Capacity and schedule

ProductCapacitySession
Flagship4–8 playersAbout 90 minutes
Smaller room A2–6 playersAbout 60 minutes
Smaller room B2–6 playersAbout 60 minutes
Full venue waveUp to 20 playersStaggered starts
  • Advance reservations are offered at any time, including outside ordinary leisure hours. The venue is not continuously staffed and has no walk-in hours.
  • Founders cover bookings outside the approximately 20-hour employee schedule.
  • One human operator should normally monitor all three rooms. Starts are staggered and resets target 10–15 minutes.
  • Target opening is within nine months of lease commencement.

Guest flow

  • Corporate groups are a core launch segment. Reception, briefing and waiting should accommodate about 20 people in approximately 35–40 m², with simple drinks but no dedicated event room.
  • The existing separated room holds workshop, storage, control and technical equipment. The existing restroom is retained.
  • At least one smaller room should be usable without crawling or climbing.
  • The unused hall area remains separated, unconditioned and outside the normal guest route.

Occupancy and toilets

The current setup has two toilets. The preliminary upper-floor plan shows them as two small cubicles in a 14.50 m² wet area with one basin; each cubicle door is drawn as 70 cm wide. The drawing does not show an accessible WC.

Twenty players remains a planning capacity, not an approved occupancy. The two toilets may be operationally workable with staggered starts, but the municipality/BH must confirm whether the current arrangement is sufficient for 20 guests plus an operator, whether one WC must be reserved for staff, and what accessible/customer facilities are required.

Approvals, safety, cameras and the toilet decision

Safety and building services

  • Human game-master supervision, cameras, communication and emergency unlocking are required at launch. AI support may be added later but is not a safety control.
  • Fog/smoke, lasers, motorized props, batteries, chargers and other effects.
  • Music, vibration and external noise.
  • Heating, cooling and fresh air should serve the three game rooms and reception/waiting area, not the whole 375 m² hall. The system remains unquoted and must be sized for actual occupancy and heat loads.
  • Elevated and crawl areas require a safe alternative in the accessible room and professional review where structural or approval-relevant.

No municipality or BH Gmunden approval discussion has happened yet. The room layout, occupancy, fire plan, HVAC, staffing model and financial forecast must be reconciled after those calls.